Electrical specifications, Table 421 ntck16 circuit card power requirements – Nortel Networks Circuit Card 311 User Manual

Page 1005

Advertising
background image

Electrical specifications

1005

Electrical specifications

Power requirements

Table 421 "NTCK16 circuit card power requirements" (page 1005)

shows

the power requirements for the NTCK16AX and NTCK16BX generic Central
Office trunk cards.

Table 421
NTCK16 circuit card power requirements

Voltage

Idle Current

Active current

+15.0 V dc

(See

1

)

170 ma

330 ma

-15.0 V dc

(See

1

)

170 ma

249 ma

+8.5 V dc

(See

2

)

101 ma

100 ma

+5.0 V dc

160 ma

322 ma

Note 1: Analog circuitry is powered with +/-12 V generated from +/-15
V. The maximum current imbalance between the +/-15 V rails is 100
ma per circuit pack.

Note 2: 8.5V is regulated to give 5 V.

Environmental specifications

Table 422 "NTCK16 circuit card environmental specifications" (page
1005)

lists the environmental specifications of the NTCK16AX and

NTCK16BX generic Central Office trunk cards.

Table 422
NTCK16 circuit card environmental specifications

Parameter

Specifications

Operating temperature

10 to 45 degrees C

Operating humidity

20 to 80% RH (non-condensing)

Storage temperature

–20 to +60 degrees C

Storage humidity

5 to 95% Relative Humidity

Pad switching

The NTCK16AX and NTCK16BX generic Central Office trunk cards support
the North American loss plan. Software configuration allows the selection of
4 dB loss pads on a per unit basis.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.