Qpc441 3-port extender cards – Nortel Networks Circuit Card 311 User Manual

Page 106

Advertising
background image

106

Option settings

S1 and S2—E33

Note: Possible jumper locations for vintage A (for different styles/series). These cards can only be
used in the option A setting:

J3—H5 or E11
J4—H17 or E7
S1 and S2—E33

Note: Connectors and loop relations:

Even loop: J1 faceplate connector, jumper at J4 or S1
Odd loop: J2 faceplate connector, jumper at J3 or S2

QPC441 3-Port Extender cards

For CS 1000M SG and MG systems, QPC441 vintage F or later must be
used in all modules.

Table 44
QPC441 3PE card installed in the NT4N41CP PII Core Net modules

Jumper Settings: Set Jumper RN27 at E35 to "A".

Switch Settings

Module

D20 switch position

NT4N41 CP Core/Net modules only

1

2

3

4

5

6

7

8

Group 0

off

on

on

off

on

on

on

on

Group 1

off

on

on

off

on

on

off

on

Group 2

off

on

on

off

on

off

on

on

Group 3

off

on

on

off

on

off

off

on

Group 4

off

on

on

off

off

on

on

on

Group 5

off

on

on

off

off

on

off

on

Group 6

off

on

on

off

off

off

on

on

Core/Net 0

(Shelf 0)

Group 7

off

on

on

off

off

off

off

on

Group 0

off

on

on

off

on

on

on

off

Group 1

off

on

on

off

on

on

off

off

Group 2

off

on

on

off

on

off

on

off

Group 3

off

on

on

off

on

off

off

off

Group 4

off

on

on

off

off

on

on

off

Group 5

off

on

on

off

off

on

off

off

Group 6

off

on

on

off

off

off

on

off

Core/Net 1

(Shelf 1)

Group 7

off

on

on

off

off

off

off

off

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.

Advertising