Table 308 pad switching algorithm – Nortel Networks Circuit Card 311 User Manual

Page 794

Advertising
background image

794

NT8D15 E and M Trunk card

Port-to-port connection loss is automatically set by software on the basis
of the port type selected in LD 16; only the port type is set by the user.

The transmission properties of each trunk are characterized by the class of
service assigned in LD 14. Transmission properties can be Via Net Loss
(VNL) or non-Via Net Loss (non-VNL).

The VNL class of service is assigned at the CLS prompt by typing VNL. The
non-VNL class of service is assigned at the CLS prompt by typing TRC
(Transmission Compensated) or NTC (Non-Transmission Compensated).

Non-VNL trunks are assigned a TRC or NTC class of service to ensure
stability and minimize echo when connecting to long-haul trunks, such as
tie trunks. The class of service determines the operation of the switchable
pads contained in each unit. They are assigned as follows:

TRC for a 2-wire non-VNL trunk facility with a loss of greater than 2
dB, or for which impedance compensation is provided, or for a 4-wire
non-VNL facility.

NTC for a 2-wire, non-VNL trunk facility with a loss of less than 2 dB, or
when impedance compensation is not provided.

See

Table 307 "Pad switching algorithm" (page 792)

for the pad switching

control for the various through connections and the actual port-to-port
loss introduced for connections between the E and M Trunk card and any
other IPE port designated as Port B.

Figure 258 "Pad orientation" (page

795)

shows the pad switching orientation.

Table 308
Pad switching algorithm

Port B pads

E and M Trunk Pads

Port-to-port loss (dB)

Port B

Transmit

D to A

Receive

A to D

Transmit

D to A

Receive

A to D

Port B to

E and M

E and M to

Port B

IPE line

N/A

N/A

Out

In

2.5

3.5

Universal
trunk (TRC)

Out

Out

In

In

0

0

IPE tie (VNL)

In

Out

In

Out

0

0

PE line

N/A

N/A

Out

In

3.0

4.0

Note: Transmit and receive designations are from and to the CS 1000. Transmit is from the CS
1000 to the external facility (digital-to-analog direction in the E and M Trunk card). Receive is to the
CS 1000 from the external facility (analog-to-digital direction in the E and M Trunk card).

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.