Page 311

Advertising
background image

Man-Machine E1 maintenance interface software

311

The Pause command works the same for Display History as it does for
the other display commands. Simply enter

D H P

to see a report on the

performance counters, one screen at a time.

Figure 75
Display History (D H) screen

As with all

Display

commands, the Pause command can be used to

display a full screen of the history report at a time, by entering

D H P

.

Clear Error

Reset the error counter to zero by entering the Clear Error (C E) command.
The error counter provides a convenient way to determine if the E1 link is
performing without errors since it can be cleared and examined at any time.

Testing

The

Test Carrier (T)

command allows tests to be run on the LEI, the

E1 link, or the CPE device. The three tests are designed to provide the
capability to isolate faulty conditions in any of these three sources. See

Table 127 "MMI Tests" (page 312)

for additional information on these three

test types. Enter the

T

command, and at the prompt, enter which of these

three tests is to be initiated. The prompt is similar to

Figure 76 "Test Carrier

(T) screen" (page 311)

.

Figure 76
Test Carrier (T) screen

Tests can be performed once, for one through 98 minutes, or continuously
(selected by entering 99 minutes), until a

Stop Test

command is entered.

Tests continue for the duration specified even if a failure occurs, and

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008