LD 10 is also used to select unit terminating impedance and balance network
impedance at the TIMP and BIMP prompts, respectively. The message
waiting interrupted dial tone and call forward reminder tone features are
enabled by entering data into the customer data block using LD 15.

See Software Input/Output Reference — Administration (NN43001-611) for
LD 10 and LD 15 service change instructions.

Table 62
OPS analog line card configuration

Application

On-premise station (ONS)

Off-premise station (OPS)

Class of

service

ONS

OPS

Loop resist

ance

0 - 460 ohm

0 - 2300 ohm

Jumper strap

setting

b

Both JX. 0 and JX 1 off

Both JX. 0 and JX.

1 off

Both JX. 0 and JX.

1 on

Loop loss dB

c

0-1.5

>1.5-2.5

>2.5-3.0

0-1.5

>1.5-2.5

>2.5-4.5

>4.5-15

TIMP

600

ohm

600

ohm

600

ohm

600

ohm

600

ohm

600

ohm

600

ohm

BIMP

600

ohm

3COM

3CM2

600

ohm

3COM

3CM2

3CM2

Gain treatm

ent

e

No

Yes

a. Configured in the Analog (500/2500-type) Telephone Administration program (LD 10).

b. Jumper strap settings JX 0 and JX. 1 apply to all eight units; "X" indicates the unit number, 0-7.
"OFF" indicates that a jumper strap is not installed across both pins on a jumper block. Store unused
straps on the OPS analog line card by installing them on a single jumper pin.

c. Loss of untreated (no gain devices) metallic line facility. Upper loss limits correspond to loop
resistance ranges for 26 AWG wire.

d. Default software impedance settings are:
ONS CLSOPS CLS
TIMP:600 ohm600 ohm
BIMP:600 ohm3COM2

e. Gain treatment, such as a voice frequency repeater (VFR) is required to limit the actual OPS loop
loss to 4.5 dB, maximum. VFR treatment of metallic loops having untreated loss greater than 15dB
(equivalent to a maximum signaling range of 2300 ohm on 26 AWG wire) is not recommended.

Individual line interface units on the OPS analog line card are configured
to either OPS (for OPS application) or ONS (for ONS application) Class of
Service (CLS) in the Single-line Telephone Administration program (LD10)
(see

Table 62 "OPS analog line card configuration" (page 133)

). LD10

is also used to select unit terminating impedance and balance network

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.

Advertising