continues for the designated duration period. The alarm finally clears when
the alarm condition is no longer detected for the designated duration period
either by self-clearing (if this function is enabled), or when the Clear Alarm
(C A) command set is entered.

In addition to bit errors, the Set Alarm function sets parameters for detecting
frame slip errors, by establishing a threshold necessary to activate an alarm.
If the threshold value is exceeded, a level 2 alarm is activated. The frame
slip threshold can be specified from 1 to 255 frame slips per time period.
The duration time period can be specified from 1 to 24 hours.

When entering the Set Alarm command set, the MMI scrolls through the
previously described series of alarm options. These options are displayed
along with their current value. Enter a new value or press Enter to retain the
current value.

Table 108 "Set alarm options" (page 242)

outlines the options

available in the Set Alarm function.

Table 108
Set alarm options

Option

Description

AL1 Threshold

Sets the allowable bit errors per second (from 3 to 9) before alarm level 1
is activated. Factory default is 10

–6

.

AL1 Duration

Sets the duration in seconds (from 1 to 3,600 seconds) that alarm level 1 is
activated. Factory default is 10 seconds.

AL2 Threshold

Sets the allowable bit errors per second (from 3 to 9) before alarm level 2
is activated. Factory default is 10

-5

AL2 Duration

.Sets the duration in seconds (from 1 to 3,600 seconds) that alarm level 2 is
activated. Factory default is 10 seconds

Frame Slip
Threshold

Sets the allowable frame slips per time period (from 1 to 255) before alarm
level 2 is activated. Factory default is 5.

Frame Slip Duration

Sets the duration in hours (from 1 to 24) that the frame slips are counted.
After this time period, the counter is reset to 0. Factory default is 2 hours.

Note: If the duration period is set too long, the Lineside T1 card can be
slow to return to service automatically even when the carrier is no longer
experiencing any errors. The Clear Alarm command must be entered
manually to restore service promptly. To avoid this, the duration period
should normally be set to 10 seconds.