Nortel Networks Circuit Card 311 User Manual

Page 546

Advertising
background image

546

NT8D09 Analog Message Waiting Line card

connection of –150 V dc at 1 Hz to activate message waiting lamps

lamp status detection

disabling and enabling of selected units for maintenance

Card interfaces

The analog message waiting line card passes voice and signaling data
over DS-30X loops and maintenance data over the card LAN link. These
interfaces are discussed in

"Intelligent Peripheral Equipment" (page 21)

.

Line interface units

The analog message waiting line card contains 16 identical and
independently configurable line interface units (also referred to as circuits).
Each unit provides 600-ohm impedance matching and a balance network in
a signal transformer/analog hybrid circuit. Circuits are also provided in each
unit to apply the ringing voltage onto the line synchronized to the ringing
current zero crossing. Signal detection circuits monitor on-hook/off-hook
status and switchhook flash detection. Four CODECs are provided to
perform A/D and D/A conversion of line analog voiceband signals to digital
PCM signals. Each CODEC supports four line interface units. The following
features are common to all units on the card:

Transmission and reception of Scan and Signaling Device (SSD)
signaling messages over a DS30X signaling channel in A10 format.

Loopback of SSD messages and pulse code modulation (PCM) signals
for diagnostic purposes.

Correct initialization of all features, as configured in software, at
power-up.

Direct reporting of digits dialed (500 telephones) by collecting dial
pulses.

Connection of –150 V dc at 1 Hz to activate message waiting lamps in
two telephones in parallel. The two telephones must be the same type or
the neon series resistor in each telephone must be 54 K ohms or greater.

Lamp status detection (does not detect a failure of either lamp when
operating in parallel).

Disabling and enabling of selected units for maintenance.

40 mA to telephones with short circuit protection.

Card control functions

Control functions are provided by the following:

a microcontroller

a card LAN interface

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.