Figure 66 set simple (s s) no screen, Figure 67 set simple (s s) yes screen, Figure 68 set mode screen – Nortel Networks Circuit Card 311 User Manual

Page 302: Figure 67 "set simple

Advertising
background image

302

NT5D33 and NT5D34 Lineside E1 Interface cards

Figure 66
Set Simple (S S) no screen

Figure 67
Set Simple (S S) yes screen

Set Mode

At the

SET MODE (S M)

command, the MMI prompts the user with the

current signaling mode, either Default (Australian P2) or Table (of bit values.)
Entering a

<CR>

accepts the current value, or the user can type in 1 to

revert to the Default, or 2 to edit the table entries. See

Figure 68 "Set Mode

screen" (page 302)

. If the user selects default, then the A/B Bit values is

reset to the Default values.

Responding to the MMI’s Set Mode prompt with "1" also results in the
line, "Signaling Bits set to Default," as in

Figure 68 "Set Mode screen"

(page 302)

.

Figure 68
Set Mode screen

However, responding to this prompt with 2 selects "Table" and allows the
user to set the A/B Bit Mode to whatever configuration the user chooses.

If "Table" is selected, the individual table values are prompted for. See

Figure 69 "Set Mode (S M): Table screen" (page 303)

and

Figure 70 "Set

Mode (S M): Table screen" (page 304)

. After each value is displayed, enter

<CR>

to do the following:

accept the current value

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.

Advertising