Table 222 power requirements – Nortel Networks Circuit Card 311 User Manual

Page 555

Advertising
background image

Electrical specifications

555

Table 222
Power requirements

Voltage
(+/-)

Tolerance

Idle
current

Active
current

Max

+ 12.0 V dc

0.36 V dc

48 mA

0 mA

48 mA

+ 8.0 V dc

0.40 V dc

150 mA

8 mA

280 mA

–48.0 V dc

2.00 V dc

48 mA

40 mA

688 mA

–48.0 V dc

5.00 V dc

0 mA

10 mA
(Note 1)

320 mA

86.0 V ac

5.00 V ac

0 mA

10 m
(Note 2)

160 mA

–150.0 V dc

3.00 V dc

0 mA

2 mA

32 mA

Note 1: Each active ringing relay requires 10 mA of battery voltage.

Note 2: Reflects the current for ringing a single station set. There may be as
many as five ringers on each line.

Foreign and surge voltage protections

In-circuit protection against power line crosses or lightning is not provided
on the NT8D09 Analog Message Waiting line card.

In-circuit protection against power line crosses or lightning is not provided
on the analog message waiting line card. When the card is used to service
off-premise telephones, primary and secondary MDF protection must be
installed. Details on installing protection devices are given in

"Environmental

specifications" (page 323)

. Off-premise telephones served by cable pairs

routed through the central office, or crossing a public right-of-way, can be
subject to a requirement for on-card protection, and MDF protectors may
not be acceptable. Check local regulations before providing such service.

In-circuit protection against power line crosses or lightning is not provided on
the Analog Message Waiting line card. When the Analog line card is used to
service off-premise telephones, the NTAK92 Off-premise protection module
must be used. Check local regulations before providing such service.

In-circuit protection against power line crosses or lightning is not provided
on the NT8D09 Analog Message Waiting Line Card. When the analog line
card is used to service off-premise telephones, the NTAK92 Off-Premise
protection module must be used. Check local regulations before providing
such service.

Overload level

Signal levels exceeding +7 dBm applied to the tip and ring cause distortion
in speech transmission.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.