Qpc471 clock controller card, Table 50 qpc471 vintage h – Nortel Networks Circuit Card 311 User Manual

Page 110

Advertising
background image

110

Option settings

Unit 0 jumper (Location E27)
Unit 1 jumper (Location E11)
Unit 2 jumper (Location D29)
Unit 3 jumper (Location D9)

Jumper:

Unit 0

Jumper

Unit 1

Jumper

Unit 2

Jumper

Unit 3

Jumper

600

3

/

4

resistive impedance

Pin 1 to 2

Pin 1 to 2

Pin 1 to 2

Pin 1 to 2

3-component complex impedance

Pin 2 to 3

Pin 2 to 3

Pin 2 to 3

Pin 2 to 3

QPC471 Clock Controller card

Table 50 "QPC471 vintage H" (page 110)

lists option settings for the

QPC471 Clock Controller card.

Table 50
QPC471 vintage H

SW1

SW2

SW4

System

1

2

3

4

1

2

3

4

1

2

3

4

61C

on

on

on

on

off

off

off

off

off

on

*

*

81

off

off

off

off

off

off

off

off

off

on

*

*

81C

on

off

off

off

off

off

off

off

**

on

*

*

81C with Fiber Network

on

off

off

off

off

off

off

off

**

on

*

*

*Cable length between the J3
faceplate connectors:

0–4.3 m (0–14 ft)

off

off

4.6–6.1 m (15–20 ft)

off

on

6.4–10.1 m (21–33 ft)

on

off

10.4–15.2 m (34–50 ft)

on

on

*If there is only one Clock Controller card in the system, set to OFF. If there are two Clock Controller
cards, determine the total cable length between the J3 connectors (no single cable can exceed 25
ft.) and set these two switch positions for this cable length, as shown above. The maximum total
(combined) length is 50 ft. Set the switches on both cards to the same settings.

**Set to ON for clock controller 0. Set to OFF for clock controller 1.

Note: FNF based-systems the total clock path length is equal to the length of the NTRC49 cable
used to connect between the two clock controller cards.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.