Table 334 xmfr receiver specifications – Nortel Networks Circuit Card 311 User Manual

Page 845

Advertising
background image

MF signaling

845

Digit

Backward direction

DOD-Tx, DID-Rx

9

1100 Hz + 1500 Hz

0

1300 Hz + 1500 Hz

KP

1100 Hz + 1700 Hz

ST

1500 Hz + 1700 Hz

STP(ST’)

900 Hz + 1700 Hz

ST2P(ST")

1300 Hz + 1700 Hz

ST3P(ST")

700 Hz + 1700 Hz

XMFR receiver specifications

Table 334 "XMFR receiver specifications" (page 845)

provides the operating

requirements for the NTAG26 circuit card.

Table 334
XMFR receiver specifications

Coding:

Mu-Law

Input sensitivity:

must accept: 0 to -25 dBmO
must reject: -35 to dBmO

Frequency sensitivity:

must accept: f +/- (1.5% + 5Hz)

Amplitude Twist:

must accept: difference of 6dB between frequencies

Signal Duration:

must accept: > 30 ms
must reject: < 10 ms

KP Signal Duration:

must accept: > 55 ms
may accept: > 30 ms
must reject: < 10 ms

Signal Interruption Bridge:

must ignore: < 10 ms

Time Shift between 2 frequencies:

(Envelop for start/stop)

must accept: < 4 ms

Coincidence between 2 frequencies:

must reject: < 10 ms

Intersignal Pause:

must accept: > 25 ms

Maximum Dialling Speed:

must accept: 10 signals per second

Noise Rejection:

Error Rate in White Noise

Better than: < 1/2500 calls
Test:
10 digit calls
nominal frequency @ -23 dBmO
ON/OFF = 50 ms/50ms
KP duration 100 ms
SNR = -20 dB
all digits

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.

Advertising