Installation, Table 175 msdl power consumption, Table 176 msdl interface switch settings – Nortel Networks Circuit Card 311 User Manual

Page 401

Advertising
background image

Installation

401

A stable ambient operating temperature of approximately 22



C (72



F) is

recommended. The temperature differential in the room should not exceed
±3



C (±5



F).

The internal power supply in each module provides DC power for the MSDL
and other cards. Power consumption and heat dissipation for the MSDL is
listed in

Table 175 "MSDL power consumption" (page 401)

.

Table 175
MSDL power consumption

Voltage

(VAC)

Current

(Amps)

Power

(Watts)

Heat

(BTUs)

+5

3.20

16.00

55.36

+12

0.10

1.20

4.15

–12

0.10

1.20

4.15

Installation

Device number

Before installing MSDL cards, determine which of the devices in the system
are available. If all 16 devices are assigned, remove one or more installed
cards to replace them with MSDL cards.

Make sure that the device number assigned to the MSDL card is not used
by an installed card, even if one is not configured. Use the MSDL planning
form, at the end of this section, to assist in configuring MSDL cards.

MSDL interfaces

Before installing the cards, select the switch settings that apply to your
system, the interfaces, and card addresses.

Table 176 "MSDL interface switch settings" (page 401)

shows the switch

positions for the DCE and the DTE interface configurations on the MSDL
card.

Figure 104 "MSDL switch setting example" (page 402)

shows the

MSDL and the location of configuration switches on the MSDL. The switch
settings shown in this figure are an example of the different types of
interfaces available. Your system settings may differ.

Table 176
MSDL interface switch settings

DCE
switch

DTE
switch

Interface

Comment

OFF

OFF

RS-232

DTE/DCE is software
configured

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.

Advertising