Nortel Networks Circuit Card 311 User Manual

Page 343

Advertising
background image

Functional description

343

Table 144
Impedance level and loop mode switch settings

Swit

ch

Description

S9/S15 Switch Setting

1

Impedance level

OFF - 120 ohm
ON - 75 ohm

2

Spare

X

3

Spare

X

4

Unit mode

OFF - Loop operates in the DTI2 mode
ON - Loop operates in the PRI2 mode

Transmission mode

A per-trunk switch (S4/S10) provides selection of the digital trunk interface
type. Refer to

Table 145 "Impedance level and loop mode switch settings"

(page 343)

.

Table 145
Impedance level and loop mode switch settings

Description

S4/S10 switch settings

E1

OFF

Not used

Line build out

A per-trunk set of three switches (S5/S11, S6/S12 and S7/S13) provides
the dB value for the line build out. Refer to

Table 146 "Trunk interface line

build out switch settings" (page 343)

.

Note: Do not change this setup.

Table 146
Trunk interface line build out switch settings

Switch setting

Description

S5/S11

S6/S12

S7/S13

0dB

OFF

OFF

OFF

Receiver impedance

A per-trunk set of four DIP switches (S8/S14 provides selection between 75
or 120 ohm values. Refer to

Table 147 "Trunk interface impedance switch

settings" (page 344)

.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.