Table 148 ring ground switch settings, Table 149 dch mode and address switch settings, Table 147 "trunk interface impedance switch – Nortel Networks Circuit Card 311 User Manual

Page 344

Advertising
background image

344

NT5D97 Dual-port DTI2 PRI2 card

Table 147
Trunk interface impedance switch settings

Description

S8/S14 switch setting

75 ohm

OFF

OFF

ON

OFF

120 ohm

OFF

OFF

OFF

ON

Ring ground switches for NT5D97AA/AB

A set of four Dip switches (S2) selects which Ring lines are connected to
ground. Refer to

Table 148 "Ring ground switch settings" (page 344)

.

Table 148
Ring ground switch settings

Switch

Description

S2 switch settingS

1

Trunk 0 Transit

OFF-Ring line is not grounded
ON- Ring line is grounded

2

Trunk 0 Receive

OFF-Ring line is not grounded
ON- Ring line is grounded

3

Trunk 1 Transmit

OFF-Ring line is not grounded
ON- Ring line is grounded

4

Trunk 1 Receive

OFF-Ring line is not grounded
ON- Ring line is grounded

DCH Address select switch for NTBK51AA daughterboard for
NT5D97AA/AB

In case of an on-board NTBK51AA D-channel daughterboard, set of four
switches (S3) provide the daughterboard address. Refer to

Table 156 "Trunk

1 switches" (page 349)

.

Note: Switch 8 of S3 (S3-8) does not require a switch setting to select
between the on-board NTBK51AA D-channel daughterboard and
an external DCHI/MSDL. The NT5D97 detects when the on-board
NTBK51AA D-channel daughterboard is used.

Table 149
DCH mode and address switch settings

Swit

ch

Description

S3 switch setting

1-4

D-channel daughterboard address

See

Table 150

"NTBK51AA
daughterboard
address select switch
settings" (page 345)

5-8

For future use

OFF

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.