Table 82 lineside t1 card - power required – Nortel Networks Circuit Card 311 User Manual

Page 186

Advertising
background image

186

NT5D11 and NT5D14 Lineside T1 Interface cards

Characteristics

Description

Signaling

Loop or ground start A/B robbed-bit

Distance to Customer Premise
Equipment (CPE) or Channel Service
Unit

0-199.6 meters (0–655 feet)

Table 81 "Lineside T1 card - line interface unit electrical characteristics"
(page 186)

provides a technical summary of the T1 line interfaces, and

Table 83 "Lineside T1 card - power required" (page 187)

lists the maximum

power consumed by the card.

T1 channel specifications

Table 81 "Lineside T1 card - line interface unit electrical characteristics"
(page 186)

provides specifications for the 24 T1channels. Each

characteristic is set by dip switches. See

"Installation and configuration"

(page 188)

for the corresponding dip switch settings.

Table 81
Lineside T1 card - line interface unit electrical characteristics

Characteristics

Description

Framing

ESF or D4

Coding

AMI or B8ZS

Signaling

Loop or ground start A/B robbed-bit

Distance to Customer Premise
Equipment (CPE) or Channel Service
Unit

0-199.6 meters (0–655 feet)

Power requirements

The Lineside T1 card requires +15 V, –15 V, and +5 V from the backplane.
One NT8D06 IPE Power Supply AC or NT6D40 IPE Power Supply DC can
supply power to a maximum of eight Lineside T1 cards. See

Table 82

"Lineside T1 card - power required" (page 186)

.

Table 82
Lineside T1 card - power required

Voltage

Current (max.)

+ 5.0 V dc

1.6 Amp

+15.0 V dc

150 mA.

–15.0 V dc

150 mA.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.

Advertising