Nortel Networks Circuit Card 311 User Manual

Page 744

Advertising
background image

744

NT8D15 E and M Trunk card

Signaling and control

The signaling and control portion of the E and M Trunk card works with the
system CPU to operate the card hardware. The card receives messages
from the CPU over a signaling channel in the DS-30X loop and returns
status information to the CPU over the same channel. The signaling and
control portion of the card provides analog loop terminations that establish,
supervise, and take down call connections.

Configuration information for the E and M Trunk card is downloaded from
the CPU at power-up and by command from maintenance programs.
Configuration messages are sent. One message is sent to configure trunk
and signaling type. The other messages are sent to each card to select the
make/break ratio and the A-Law and µ-Law modes.

The signaling and control circuits on the card perform the following functions:

provide an interface between the card and the system CPU

— transmit PCM signals from each of the four units to one DS-30X

timeslot in A10 format (ready to send/clear to send—flow control,
handshake format)

— transmit and receive signaling messages over a DS-30X signaling

channel in A10 format

decode received messages to set configuration and activate/deactivate
interface relays for PCM loopback diagnostic purposes

decode outpulsing messages (one per digit) from the CPU to drive
outpulsing relays at 20 pps, 10 pps1 (primary), or 10 pps2 (secondary)

monitor signals from the trunk interface and generate a message when
required for each state change

control disabling and enabling of unit or card

control A-Law and µ-Law operation modes

control transmission pad settings

The signaling and control portion of the E and M Trunk card works with the
system CPU to operate the card hardware. The card receives messages
from the CPU over a signaling channel in the DS-30X loop and returns
status information to the CPU over the same channel. The signaling and
control portion of the card provides analog loop terminations that establish,
supervise, and take down call connections.

Configuration information for the E and M trunk card is downloaded from
the CPU at power-up and by command from maintenance programs. Seven
configuration messages are sent. One message is sent to each of the four

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.

Advertising