Nt8d22 system monitor, Table 36 nt8d22 sw1 – Nortel Networks Circuit Card 311 User Manual

Page 97

Advertising
background image

NT8D22 System Monitor

97

Settings

Frequency

Amplitude

P1

P2

P3

25 Hz

86 V ac

open

2–5

8–11

open

50 Hz

70 V ac

1–4

7–10

open

open

50 Hz

80 V ac

3–6

9–12

open

open

NT8D22 System Monitor

The master system monitor, located in the column with CP 0, must be
numbered 0. Slave system monitors are numbered from 1 to 63.

For examples of system monitor option settings in basic configurations, see
"Sample settings for NT8D22 System Monitors."

Configure the system monitor in Remote Peripheral Equipment (RPE)
columns as slaves. There is no serial connection between RPE columns.

Table 36
NT8D22 SW1

Position

SW1 function

1

2

3

4

5

6

7

8

Not used
Meridian 1 columns only

on
off

Position 1 is OFF (Meridian 1
columns only)
Not used
Position 1 is ON, master column
contains CP:master

slaves

off
off
on
off

DC-powered system
AC-powered system

on
off

PFTU is activated by this column
due to over-temperature
PFTU is not activated by this
column

on
off

Position 1 is OFF (Meridian 1
columns only)
Not used
Not used

off
on
off

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008