Nortel Networks Circuit Card 311 User Manual

Page 694

Advertising
background image

694

NT8D14 Universal Trunk card

The jumper strap settings must be changed, as shown in

Table 251 "Jumper

strap settings - extended range (NT8D14BA, NT8D14BB, NT8D14BB)"
(page 692)

, for the following:

For CO/FX/WATS or TIE trunk loops exceeding 1524 meters (5000 ft.)

DID trunks exceeding a loop resistance of 600 ohms

RAN trunks operating in pulse start or level start modes

Figure 216 "Universal trunk card - jumper locations for NT8D14BA and
NT8D14BB Release 9 and below" (page 695)

shows jumper locations on

the universal trunk card (vintage BA).

For most applications, the jumper strap settings remain set to the standard
configuration as shipped from the factory. See

Table 255 "Jumper strap

settings - factory standard (NT8D14BA, NT8D14BB)" (page 698)

.

The jumper strap settings must be changed, as shown in

Table 256 "Jumper

strap settings - extended range (NT8D14BA, NT8D14BB, NT8D14BB
Release 10 and up)" (page 698)

, for the following:

For CO/FX/WATS or TIE trunk loops exceeding 1524 meters (5000 ft.)

DID trunks exceeding a loop resistance of 600 ohms

RAN trunks operating in pulse start or level start modes

Figure 218 "Universal trunk card - jumper locations for NT8D14BA and
NT8D14BB Release 9 and below" (page 702)

shows jumper locations on

the universal trunk card (vintage BA).

Note: Refer to Circuit Card: Description and Installation (NN43001-311)
for vintage AA jumper strap settings.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.

Advertising