Functional description

731

Four-wire E and M signaling type I and II, two-way dial repeating (ESN
and Non-ESN)

— echo suppression for type I

— Switchable seven dB and 16 dB for carrier interface for ESN

applications

— Transmit and receive of voice through two separate paths

Type I signaling through E and M leads

— Type II signaling

Near-end seizure with MA/MB leads

Far-end detection with EA/EB leads

Paging trunk loop OAID operation

— Support access by low resistance path at the PA/PB lead.

— All call zone paging is not supported.

Two to four-wire conversion of the transmission path

Trunk unit functions

The functions provided by each unit on the E and M Trunk card include
2-wire signaling, 4-wire signaling, and paging operation as follows:

2-wire, E and M Type I signaling (see

Figure 228 "E and M Type I

signaling" (page 732)

) with:

— near-end seizure and outpulsing with M lead

— ground detection with E lead

— voice transmission through tip and ring for transmit and receive

4-wire, E and M Type I and II signaling (see

Figure 229 "E and M Type II

signaling" (page 732)

), 2-way dial repeating with:

— echo suppression for Type I signaling

— switchable 7 dB and 16 dB pads for carrier interface

— voice transmission and reception through two separate paths

— Type I signaling through E and M leads

— Type II signaling with near-end seizure by SB/M leads and far-end

detection by E/SG lead

4-wire, DX signaling (see

Figure 230 "4-wire DX signaling" (page 734)

)

Nortel Communication Server 1000