NT8D41AA Serial Data Interface Paddle Board

Table 317
SDI paddle board baud rate switch settings

Port 1 – SW2

Port 2 – SW3

Baud

rate

1

2

3

4

1

2

3

4

150

off

off

on

on

off

off

on

on

300

off

on

off

on

off

on

off

on

600

off

off

off

on

off

off

off

on

1200

off

on

on

off

off

on

on

off

2400

off

off

on

off

off

off

on

off

4800

off

on

off

off

off

on

off

off

9600

off

off

off

off

off

off

off

off

DTE/DCE/Fiber mode

Each serial port can be configured to connect to a terminal (DTE
equipment), a modem (DCE equipment), or a Fiber Superloop Network card.
Instructions for setting the switches SW5, SW6, SW7, and SW8 are shown
in

Table 318 "NT8D41AA DTE/DCE/Fiber switch settings" (page 816)

.

Table 318
NT8D41AA DTE/DCE/Fiber switch settings

Port 1 – SW5

Port 1 – SW6

Mode

1

2

3

4

5

6

1

2

3

4

5

6

DTE (terminal)

on

on

on

on

on

on

off

off

off

off

off

off

DCE (modem)

off

off

off

off

off

off

on

on

on

on

on

on

NT1P61 (Fiber)

on

on

on

on

on

off

off

off

on

on

on

on

Port 2 – SW7

Port 2 – SW8

DTE (terminal)

on

on

on

on

on

on

off

off

off

off

off

off

DCE (modem)

off

off

off

off

off

off

on

on

on

on

on

on

NT1P61 (Fiber)

on

on

on

on

off

off

off

off

on

on

on

on

Software service changes

Once the NT8D41 SDI paddle board has been installed in the system,
the system software needs to be configured to recognize it. This is done
using the Configuration Record program LD 17. Instructions for running
the Configuration Record program are found in Software Input/Output
Reference — Administration
(NN43001-611).