310

NT5D33 and NT5D34 Lineside E1 Interface cards

to determine if an alarm condition has been corrected. Clear the error
counter, wait a few minutes, and display the performance to see if any errors
occurred since the counter was cleared.

The MMI display reports on these performance counters through the

Display Performance (D P)

or the

Display History (D H)

commands.

Display Performance

Entering the

Display Performance (D P)

command displays

performance counters for the past hour. A screen similar to

Figure 74

"Display Performance (D P) screen" (page 310)

appears.

Figure 74
Display Performance (D P) screen

Each column, except the error counter, indicates the number of errors in the
current hour and is reset to zero every hour on the hour. Just before the
performance counters are reset to zero, the values are put into the history
log.

The error counter indicates the number of errors since the error counter
was cleared.

The Pause command can be used to display a full screen at a time, by
entering

D P P

. If more than one screen is to be displayed, the MMI scrolls

until the screen is full, then stops. When ready to see the next screen,
press any key. The display shows one more screen, and stops again. This
continues until the entire display has been shown.

Display History

Entering the

Display History (D H)

command displays performance

counters for each hour of the past 24 in reverse chronological order,
beginning with the last full hour. A screen similar to

Figure 75 "Display

History (D H) screen" (page 311)

appears.