NT8D09 Analog Message Waiting Line card

Table 220
Analog message waiting line card - power requirements

Voltage
(+/–)

Tolerance

Idle
current

Active
current

Maximum

+12.0 V dc

0.36 V dc

48 mA

0 mA

48 mA

+8.5 V dc

0.40 V dc

150 mA

8 mA

280 mA

–48.0 V dc

2.00 V dc

48 mA

40 mA*

688 mA

–48.0 V dc

5.00 V dc

0 mA

10 mA**

160 mA

86.0 V ac

5.00 V ac

0 mA

10 mA***

160 mA

–150.0 V dc

3.00 V dc

0 mA

2 mA

32 mA

* Current required for each line off-hook

** Each active ringing relay requires 10 mA of battery voltage

*** Reflects the current for ringing a single DN telephone. There may be as many
as five ringers on each line.

Table 221 "Power requirements" (page 554)

provides the power

requirements for the analog message waiting line card.

Table 221
Power requirements

Voltage

(+/-)

Tolerance

Idle

current

Active

current

Max

+ 12.0 V DC

0.36 V DC

48 mA

0 mA

48 mA

+ 8.0 V DC

0.40 V DC

150 mA

8 mA

280 mA

- 48.0 V DC

2.00 V DC

48 mA

40 mA

688 mA

- 48.0 V DC

5.00 V DC

0 mA

10 mA

(Note 1)

320 mA

86.0 V AC

5.00 V AC

0 mA

10 mA

(Note 2)

160 mA

-150.0 V DC

3.00 V DC

0 mA

2 mA

32 mA

Note 1: Each active ringing relay requires 10 mA of battery voltage.

Note 2: Reflects the current for ringing a single station set. There may be as
many as five ringers on each line.

Table 222 "Power requirements" (page 555)

provides the power

requirements for the NT8D09 Analog Message Waiting Line Card.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.