Table 192 – Nortel Networks Circuit Card 311 User Manual

Page 488

Advertising
background image

488

NT7D16 Data Access card

Table 192
RS-232-C and RS-422 pinouts for first three DAC ports

I/O cable

RS-232-C

Pair

Pin

Pair

color

Unit no.

Signal

Pin no.

RS-422

Signal

Patch pair

or

octopus

1T

26

W-BL

UNIT 0

TD0

2

RDA0

1R

1

BL-W

RD0

3

RDB0

2T

27

W-O

DTR0

20

SDA0

2R

2

O-W

GND0

7

SDB0

Connector

3T

28

W-G

DCD0

8

1

3R

3

G-W

DSR0

6

4T

29

W-BR

RI0

22

4R

4

BR-W

CTS0

5

5T

20

W-S

UNIT 1

TD1

2

RDA1

5R

5

S-W

RD1

3

RDB1

6T

31

R-BL

DTR1

20

SDA1

6R

6

BL-R

GND1

7

SDB1

Connector

7T

32

R-O

DCD1

8

2

7R

7

O-R

DSR1

6

8T

33

R-G

RI1

22

8R

8

G-R

CTS1

5

9T

34

R-BR

UNIT 2

TD2

2

RDA2

9R

9

BR-R

RD2

3

RDB2

10T

35

R-S

DTR2

20

SDA2

10R

10

S-R

GND2

7

SDB2

Connector

11T

36

BK-BL

DCD2

8

3

11R

11

BL-BK

DSR2

6

Note 1: The RS-232 pinout follows the standard set by the QPC723 RILC.

Note 2: The RS-422 pinout follows the standard set by the QPC430 AILC (first pair: Receive Data;
second pair: Send Data). Receive and Send are designated with reference to the DTE; therefore,
they must be turned over in the cross-connect since most DTE have first pair as Send Data and
second pair as Receive Data.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

01.04

Standard

Release 5.0

23 May 2008

Copyright © 2003-2008, Nortel Networks

.