12–17

Creating Bar Graphs, Indicators, Numeric Displays

Publication 2711-6.0

Editing State Text

The Text field contains the text that will appear for each state. The
default text is the state number (ST 0). Double-click in the cell to
edit the text.

Other text fields control how the text is formatted for each state.

Entering State Values

If Value was selected in the Read area of the Properties tab, the Value
field appears for each state. This field defines the numeric value at
the read tag address that triggers the state to display.

The range of the value you enter must be within the range of the
Data Format selected on the Properties tab. The default value for
each state is the state number (0 to 1,999).

Data Format

Range

Binary➀

0000 0000 0000 0000 to
1111 1111 1111 1111

Unsigned Integer

0 to 65535

Signed Integer

-32768 to +32767

4-BCD

0 to 9999

Hexadecimal➀

0 to FFFF

Octal➀

0 to 177777

➀ Formats provided for data entry. The terminal does not display/transfer these formats.