Downloading to a terminal using pass-through – Rockwell Automation 2711-ND3 PanelBuilder v2.60 Software User Manual User Manual

Page 401

Advertising
background image

23–13

Validating and Transferring Applications

Publication 2711-6.0

This section shows how to download an application from a computer
on the DH+ link to a terminal on a Remote I/O or DH-485 link.

Before downloading an application:

check cable connections.

enable Pass-Through in the Block Transfer dialog (page 20–11).

configure the DH+ driver using RSLinx or INTERCHANGE.

!

ATTENTION: If downloading with the processor in
run mode, verify the rack address of the target terminal.
Downloading to an incorrect rack address may result in
unexpected operation or damage to equipment.

To download an application to a terminal using Pass-Through:

Choose Download from the Application menu.

Select the Download parameters.

Application is validated and translated to a .PVA file.

Terminal resets, verifies and starts application.

PanelBuilder software and terminal display status of download.

Open the application you want to download.

Enter name of .PVA file in which to
save the translated .PBA file or click
Browse to search for a file.

Select Operator Terminal via Pass-Through

Select RSLinx or
INTERCHANGE Driver

Click OK to start
download.

DH+ is active driver

Click Setup to configure
Remote I/O or DH-485
Pass-Through parameters
(pages 23–14, 23–15).

If errors or warnings are detected, the Exceptions dialog opens.
You must correct errors before download can proceed.
Warnings should be corrected, but the download will proceed.

DOS File
Memory Card

Downloading to a
Terminal using Pass-Through