Working with Tags

Publication 2711-6.0

Field

Notes

Valid Characters

Description

Node Name

➀➁

The node with which
you want this tag
associated

Maximum characters = 32

A – Z, a – z, 0 – 9

hyphen (–), underscore(_),
percent (%)

if you type an invalid character, the Tag Editor beeps and
does not display it

node name cannot be identical to a tag name or terminal
name

the node name must match the controller name entered
in the Communication Setup dialog (Terminal Setup)

node name cannot begin with 0 – 9, hyphen, or percent

node names are not case-sensitive

do not use blanks, tabs, carriage returns, non-printable
characters

Address

➀➁

The data table
address within the
processor for the tag

Maximum characters = 32
For more information on valid
addresses, refer to your
processor’s user manual.

do not use blanks, tabs, carriage returns, non-printable
characters

Initial Value

The starting value for
the current tag in
engineering units

Maximum characters = 24

0 – 9

e, E, +, – and period

if the Data Type is bit, enter
either 0 or 1

do not use blanks, tabs, carriage returns, non-printable
characters

maximum precision is 6 places to the right of the decimal
point for non-floating point values

if present, a sign (+ or –) for the number must be first (+
is the default)

if present, a sign for the exponent must immediately
follow the e or E

provides a preset value for numeric entry objects only

no entry = default of 0

Update Frequency

The rate at which you
want the terminal to
obtain data

1 – 9

where 1 is the fastest update
rate

does not apply to remote I/O

Alternate Methods:
Type the update frequency, 1 to 9.
Use the TAB key to move to the Update
Frequency field and press ALT+

to display

the list of available formats.

Scaling

Scale:
‘m’ in y = mx + b
Offset:
‘b’ in y = mx + b

The values you want
to use to convert the
current tag’s
processor integer
value (‘x’) to
engineering units (‘y’)

Maximum characters = 12

0 – 9

e, E, +, – and period

do not use blanks, tabs, carriage returns, non-printable
characters

maximum precision for scale is 6 places to right of
decimal point

maximum precision for offset is 6 places to right of
decimal point

if present, a sign (+ or –) for the number must be first (+
is default)

if present, a sign for the exponent must immediately
follow the e or E

Data Entry Limits ➂
Minimum
Maximum

The minimum and
maximum values that
can be assigned to
the tag

Maximum characters = 12

0 – 9

e, E, +, – and period

do not use blanks, tabs, carriage returns, non-printable
characters

maximum precision is 6 places to the right of the decimal
point

if present, a sign (+ or –) for the number must be first (+
is the default)

if present, a sign for the exponent must immediately
follow the e or E

➀ Required fields for the Table View
➁ Required fields for the Form View

These fields appear only when the data type is 4BCD, signed integer, unsigned integer, IEEE Float.