Uploading on a local dh+ link – Rockwell Automation 2711-ND3 PanelBuilder v2.60 Software User Manual User Manual

Page 409

Advertising
background image

23–21

Validating and Transferring Applications

Publication 2711-6.0

This section shows how to upload an application from a DH+
terminal on the DH+ link to your computer. The computer and
terminal are each a separate station on the DH+ link.

Before uploading application:

check cable connections. See Publication 2711-6.1

configure the DH+ driver using RSLinx or INTERCHANGE.

Note: The computer runs at 57.6K baud forcing the DH+ link and
terminal to use the same rate. Set the terminal’s DH+ network to this
baud rate before uploading an application.

Choose Upload from the Application menu.

Select the Upload parameters.

When the upload is complete, the application opens in PanelBuilder.

PanelBuilder software and terminal display status of upload.

Select Local Network Operator Terminal

Click Setup to verify station
address of the terminal. The
address shown must match the
address in the Communication
Setup dialog.

Click OK to start upload.

DH+ is active driver

Under Presets, select:

S Original to upload presets (initial values)

defined for inputs.

S Current States to upload current input

values in terminal.

Select RSLinx or
INTERCHANGE Driver

Enter name of .PVA file in which to
save the uploaded application or
click Browse to search for a file.

Select DH+/RS232.

Uploading on a
Local DH+ Link