Troubleshooting

F–5

Publication 2711-6.0

Problem

Recommended Action

Cause

When downloading to an Operator
Terminal you get this error:

Transfer

orted – na e to send

In the INTERCHANGE Device. Config.
utility, the incorrect Interrupt (IRQ) is set
for the COM Port.

Set the correct Interrupt for the COM port.

COM Port 1 typically uses Interrupt (IRQ) of 4.
COM Port 2 typically uses Interrupt (IRQ) of 3.

“Transfer Aborted – unable to send
commands to terminal”

In the INTERCHANGE Device. Config.
Utility, the baud rate or another driver
parameter is set incorrectly.

Set the correct baud rate or other driver parameter. To check
the PanelView terminal’s communication parameters, select
Communication Setup from the terminal’s Configuration Mode
menu.

Incorrect cabling.

Check the cable.

When downloading to an Operator
Terminal you get this error:

“Command Failed – PCCCSTS02,
Remote station did not
acknowledge command.”

In the INTERCHANGE Device. Config.
Utility, parameters for the DF1 on COM
Port driver are incorrectly set.

Parameters for the DF1 on COM Port drivers must be set to:

Error Detect=CRC
Parity=None
Baud Rate=19200

INTERCHANGE Command Failure
PCCCEXT17––Timed out,
1771 backplane module not
responding

During a Remote I/O transfer,
PanelBuilder was unable to get a
response to a command. Probable
causes are: disconnected node device,
high network activity; low baud rate.

Verify that the PanelView terminal has a valid Remote I/O
network connection and that its application matches the
controller’s block transfer ladder logic. Retry the operation.

RNA: Error $C00A placing device
#n online

INTERCHANGE could not start the
driver associated with port #n of your
computer.

Use the INTERCHANGE Device Configuration Utility to check
the driver configuration. The driver may be set for a different
baud rate than the physical network.

The currently installed
INTERCHANGE driver cannot
download to the selected terminal.

The type of network transfer you are
attempting requires a different driver
than the one currently loaded on your
computer.

Configure the appropriate driver using the INTERCHANGE
Device Configuration Utility and then reboot computer.

When downloading an application
on a network using a KA5 bridge
(DH+<>DH485), the download
does not exit properly.

The download completes but does not
exit properly.

When the download is complete, select the CANCEL button on
the Download dialog.

Gateway device node is not active.

A Gateway device was not found at the
specified node address on the local
network.

Verify that a Gateway device is at the specified address or
change the node address in the File Transfer Setup dialog to
match the terminal’s network address.

Local Gateway device does not
support bridging operations or
remote network device is not an
operator terminal.

The local gateway device cannot pass
commands to another physical network
or the device on the remote network is
not an Operator Terminal.

In the File Transfer Setup dialog (page , verify that you have
entered the correct Gateway Node Address, Terminal Node
Address, and Link ID numbers.

Local network device is not an
operator terminal.

The specified device on the local
network is not an operator terminal.

Check the node address of the PanelView terminal in the File
Transfer Setup dialog.

Downloading with RSLinx

Problem

Cause

Recommended Action

In Windows 95, this error occurs
during a download: “Unable to start
AB-KT–1 because duplicate nodes
were found on the network”.

The computer running the RSLinx driver
is assigned the same node address as
another computer running RSLinx on the
network.

Run RSLinx and change the node address for one of the
computers.