23–20
Validating and Transferring Applications
Publication 2711-6.0
To upload an application using a DH485 Driver:
➀ Choose Upload from the Application menu.
➁ Select the Upload parameters.
➃ When the upload is complete, the application opens in PanelBuilder.
➂ PanelBuilder software and terminal display status of upload.
Enter name of .PVA file in which to
save the uploaded application or
click Browse to search for a file.
Select Operator Terminal
Click OK to start
upload.
Select the type of terminal from which
you are uploading application.
Under Presets, select:
S Original to upload presets (initial values)
defined for inputs.
S Current States to upload current input
values in terminal.
Select RSLinx or
INTERCHANGE Driver
For DH-485 or RS-232 (DH485 protocol)
terminals, click Setup to verify node
address of terminal.
Shows DH485
as active driver