Errors and Informational Messages from RNA.EXE
This message occurs normally at shutdown.
RNA removed from memory.
This parameter for the -b argument (indicating number of solicited
message buffers to use) given on the command line for RNA.EXE
was out of allowed message range of 1 to 40. A default of 20
solicited buffers will be used.
RNA: -b must be 1-40, using default of 20
The format of the options given on the command line for RNA.EXE
were invalid. Correct the option(s) and start RNA.EXE again.
RNA: illegal option –– <option>
RNA: invalid option
RNA: invalid option (option); must begin with ‘–’
RNA: option requires an argument –– <option>
The number of packet buffers, <num> requested on the command
line cannot be created. If your buffers were loaded into upper DOS
memory (the default), your upper DOS memory may be full.
Specify -e0 on the RNA.EXE command line to force the buffers to
use low DOS memory.
RNA: ERROR – cannot create <num> packet buffers
The number of unsolicited buffers, <num>, requested on the
command line cannot be created. If your buffers were loaded into
upper DOS memory (by no additional command line options), it may
be full. Specify -e0 on the RNA.EXE command line to force the
buffers to use low DOS memory.
RNA: ERROR – cannot create <num> unsolicited data items.
The RNATSR was loaded from DOS. It cannot be uninstalled with
Windows running. Exit to DOS to uninstall the RNATSR.
RNA: RNATSR loaded before Windows, cannot uninstall from Windows
Other TSRs have been installed after the RNATSR. They must be
removed from memory before the RNATSR can be uninstalled.
RNA: Cannot uninstall RNATSR; not at end of INT 2F chain
The RNATSR must be installed before running RNA.EXE.
RNA: RNATSR is not installed.