Rockwell Automation 2711-ND3 PanelBuilder v2.60 Software User Manual User Manual

Page 37

Advertising
background image

2–13

Installation

Publication 2711-6.0

This dialog opens for the 1747-PIC (DH485) on COM Port
driver.

Unique number assigned
to INTERCHANGE driver
(This is not the computer’s COM port.)

COM Port Parameters should be set to:
COM Port 2 typically uses Interrupt (IRQ) 3

or

COM Port 1 typically uses Interrupt (IRQ) 4

DH-485 Station Address (or Node
Address) of the Computer is typically 0.

Default Driver Name
(can be edited)

Disables driver configuration
temporarily without removing
it from Configured Devices
list.

3. Edit parameters and click OK when done.

The parameters are specific to the communications card installed
in your computer or the type of connection you will be using to
transfer files.

Important:

You must set Interrupts for all INTERCHANGE
drivers.

The configured driver appears under the Configured Devices list.

Configured Devices:
NAME

Refers to driver name

DEVICE Refers to selected driver
PORT

Refers to unique number assigned
to INTERCHANGE driver

STATUS Shows whether driver is enabled/disabled

Important:

Do not configure more than one driver for the
same communication port.

Advertising