Software Error and Warning Messages

D–7

Publication 2711-6.0

Message

What to do

Meaning

The PanelView terminal can only use 255
screens, no more screens can be created.

The maximum number of screens is 255.

The specified path for the translated file is
invalid. The translated application file could
not be opened.

File could not be opened during a download.

Check path of specified file.

Too many files currently open. Translated
application file cannot be opened.

File could not be opened because too many
other files or programs are open.

Close other files or applications and try again.

Unable to create application file. Check if disk
write protected.

Disk may be write protected or network
partition has read only access.

If writing to floppy, check write protect. If
writing to a network file, verify write privileges.

Unable to load configuration utility.

Could not load the InterChange Config. utility.

Check that INTERCHANGE Software is
installed.

Unable to load file. Not a PanelBuilder file or
file is corrupted.

File did not pass the Cyclic Redundancy
Check (CRC). This may occur if the file is of
the wrong type or contains corrupted data.

Check that the file is a .PBA file (not .PVA).
If file is corrupted, it must be recreated.

Unable to load file. Application file created
with incompatible version of PanelBuilder.

Application file was created using a newer
release of the configuration software.

Recreate file with a released version of
PanelBuilder Configuration Software.

Unable to load font file (file name). Display
on the screen may not be correct. You may
need to re-install PanelBuilder.

The font file could not be found in its normal
location or is an invalid font file.

Check the name and location of the font file.

Unable to load help file.

Low memory error.

Close other Window applications and retry. If
unsuccessful, the program will exit. You can’t
recover from this error.

Unable to load PanelView terminal fonts.
Font file PB900.FON must be in same
directory as PBWIN.EXE.

Font file is not in its normal location.

Move the PB900.FON file into the same
directory as PBWIN.EXE (AB\PBWIN).

Unable to open exceptions window.

Microsoft Windows is out of resources or user
memory.

Close other applications and retry. If error
reoccurs, exit Windows, reboot , and retry.

UNABLE TO OPEN FILE.
This file was created by PanelBuilder 900
demonstration software.

Application file was created using a Demo
release of the PanelBuilder configuration
software.

Recreate file with a released version of
PanelBuilder Configuration Software.

Unable to open file for reading. File not
loaded.

Read error may occur if a file is corrupted or a
data timeout has occurred on network.

Check for valid access to file. Try to load
application again.

Unable to open screen list window.

Microsoft Windows is out of resources or user
memory.

Close other applications and retry. If error
reoccurs, exit Windows, reboot, and retry.

Unexpected EOF or Error: (file name)

File error. Operation will not continue.

Check for corrupted file.

Unknown fault. Unable to continue.

Unknown fault occurred.

Close application, exit Windows, and reboot.

Upload data may be corrupted. Save
application again and retry download.

Internal error detected.

Cancel download, resave application and
retry download. If error reoccurs, call
Allen-Bradley technical support.

Validating, translating and downloading
application.

Message appears during downloads.

Press the Cancel button to cancel the
download or continue with download.

Value out of range.

Entered value is not in acceptable range.

Enter a value within acceptable ranges.