Working with Applications and Screens

Publication 2711-6.0

Setting Preferences for Opening Applications

You can control the behavior of PanelBuilder when opening an
application. Choose Preferences from the Application menu.

Shows information
about this dialog

Show Project Database Restore Dialog

Select this check box to display the Project Database Restore dialog
each time you an open an application. This dialog prompts you to:

replace duplicate tags and devices in the project database with
those in the application.

add application tags and devices to the project database if they are
missing.

This is the default option. To add missing tags and replace duplicate
tags in the project database without showing the Project Database
dialog, disable this check box and select the other two boxes.

Always Add Missing Tags & Devices

Select this check box and disable the first check box to add missing
tags and devices to the project data database without opening the
Project Database dialog. This option is equivalent to clicking the
Add All button on the Project Database dialog.

Always Replace Duplicate Tags & Devices

Select this check box and disable the first check box to replace
duplicate tags and devices in the project database without opening
the Project Database dialog. This option is equivalent to clicking the
Replace All button on the Project Database dialog.

Important:

If you disable all check boxes, the verification process
will not occur and you may lose tag or device data.