D - software error and warning messages, Software error and warning messages, Appendix – Rockwell Automation 2711-ND3 PanelBuilder v2.60 Software User Manual User Manual

Page 447

Advertising
background image

Appendix

D

Publication 2711-6.0

Software Error and Warning
Messages

This appendix lists messages that may appear during the
configuration of an application. Messages are listed alphabetically.

Message

Meaning

What to do

AB Utilities error creating project.

Project couldn’t be created. Cause could be
full disk or a write protected network partition.

Check available disk space. Or verify your
computers write privileges on network.

AB Utilities failed to initialize.

PanelBuilder could not initialize the AB
Utilities during startup because SHARE.EXE
is not running.

The PanelBuilder installation should add
SHARE.EXE to your AUTOEXEC.BAT file.
See README.TXT in C:\AB for details.

Application has exhausted terminal ID space.
Reduce number of objects in application and
retry.

The application contains more objects than
the application can support.

Reduce the number of objects on a screen
and try again.

Translation Failure!

Error occurred while translating a .PBA
application to a .PVA file for the terminal.

Check for validation error and warning
messages. Try to download again.

Attempt to recover data from (file name)
failed! Error Code: (code number)

Attempt to load data from terminal has failed.

Check network connections and try again.

Cannot create cancel dialog.

Couldn’t create print cancel dialog.

This warning doesn’t affect the print request,
but you may be unable to cancel the request.

Cannot create device context.

Printer driver could not be accessed because
of a corrupted print driver, no printer selected,
or an unstable Windows environment.

Check the Print Setup settings and reboot
computer. If the error reoccurs try another
print driver or reinstall the original driver.

Cannot create error logfile (PB550ERR.LOG).

Error log file couldn’t be created because of a
full disk or write protect condition.

Check available disk space or write
protection.

Cannot create new TAGMAN.

Internal error indicates a possible low memory
condition.

Exit the application and try again. If the error
reoccurs, contact A-B support.

Cannot delete device context.

Printer driver couldn’t be closed. Cause could
be an unstable Windows environment.

Close other applications and try again. If the
error reoccurs, exit Windows, reboot your
computer, and try again.

Cannot find desired terminal in Terminal
catalog.

The CATALOG.DAT file, which stores the
terminal type, is missing or corrupted.

Contact A-B technical support.

Cannot delete error logfile (PB550ERR.LOG).
New logfile will not be created.

On startup, PanelBuilder couldn’t delete the
log file. Cause could be a write protect error
or a SHARE violation.

Check access attributes of the file.

Otherwise exit Windows and reboot computer.
This should clear SHARE violation. If the
error reoccurs, delete PB900ERR.LOG in c:
\ab\pbwin directory and try again.

Cannot find or cannot load the Application
File Transfer Utility.

The WINPFT.EXE executable failed to load.

Verify that WINPFT.EXE is in the same
directory as PBWIN.EXE. If the file is not
there, reload the file from the installation disk.

Cannot create the abort dialog box.

Abort dialog couldn’t be initialized. Windows
may be low on resources.

Close applications and try again. If error
reoccurs, exit Windows, reboot and retry.

Cannot initialize print device.

Printer couldn’t be initialized.

Check the Print Setup settings and try again.

Cannot load the Protocol Translate server

PanelBuilder can’t load required files. Editing
the PB550.INI file can cause this error.

Reboot computer and try again. If error
continues, re-install PanelBuilder.

Cannot load the Terminal Specification server

PanelBuilder can’t load required files. Editing
the PB550.INI file can cause this error.

Reboot computer and try again. If error
continues, re-install PanelBuilder.

Advertising