Software Error and Warning Messages

D–3

Publication 2711-6.0

Message

What to do

Meaning

Delete Project From Database.
Are you sure?

The selected project tag database will be
permanently removed.

Select Yes to delete the project or No to
cancel operation.

Disk is full. Translated file cannot be saved.

Not enough disk space to save translated file
during a download.

Check available disk space.

Enter tag name before pressing Edit Tag
button.

Pressed Edit Tag button before entering a
tag name.

Before pressing Edit Tag button, there must
be a tag to edit (enter a tag name).

Error closing file. File may not be valid.

The file failed to close. Cause could be a full
disk or restricted access to network.

Check the amount of available disk space or
for valid access to network file.

Error executing application.
There is not enough memory to execute
<program name>. Please close an
application.

There is not enough memory to start another
session of PanelBuilder Configuration
Software.

Close an application and restart PanelBuilder.

Error importing graphic file.
Verify file is in correct format.

The graphic is too large or in the wrong
format.

.BMP graphic must not exceed pixel size of
display.

Error: Invalid data, missing state data!

Error while reading state data. This indicates
a corrupted edit session.

Close application without saving and retry. If
error reoccurs, contact Allen-Bradley support.

Error loading the font file.

Font file cannot be found or read.

Check location and name of font file. Font file
may need to be recreated.

Error reading application file.
File cannot be loaded.

A read error occurred. File may be corrupted
or a data timeout has occurred on network.

Check for valid access to the file. Try to load
application again.

Error writing application file.
Application not saved.

Disk is full, disk doesn’t exist or the file name
is invalid.

Check available disk space; verify validity of
file/path name; try to save application again.

Error writing application file to disk.

PanelBuilder was unable to write the .PVA
application file. Probable cause is full disk.

Check disk space and try again.

Failure reading file during decompress.
Failure writing file during decompress.
Failure opening file during decompress.
Failure closing file during decompress.

Errors occur during an upload. Cause could
be internal errors or bad floppy disk.

Exit the application and restart. Check for
bad floppy disk. If the error reoccurs, contact
A-B technical support.

File close failed:
(file name)

Upload operation couldn’t close file. Cause
could be a full disk or write protection.

Exit application and restart windows. If the
error reoccurs, contact A-B technical support.

File decompress fail:
(file name)

Compressed application file is corrupt.

Try again. If the error reoccurs, contact
A-B technical support.

File Error – Cannot find ISPCORE.DLL

PanelBuilder would not start because the
default path C:\AB\BIN is missing from
AUTOEXEC.BAT file.

Make sure your AUTOEXEC.BAT file contains
the default path C:\AB\BIN.

File rename error:
(file name)

A file exists with the same file name.

Check for duplicate file names and try again.

Filename Specified for Download Cannot
be same as Application Filename.

Downloaded application using the same file
name and type as the opened file. The file
name or type must be different to prevent the
download file from overwriting application file.

Specify a different file name or file type.
Normally the file type for a downloaded
application is .PVA.

Incompatible AB Utilities version.

PanelBuilder detected incorrect version of the
A-B utilities software on startup.

Reinstall the AB Utilities disk or contact
Allen-Bradley for support.

Insufficient available Windows resources to
run this application. Try closing some other
applications and try again.

There are too many applications running.

Close all running applications and try again.

Invalid application file.
Unable to restore all objects.

Internal error occurred while restoring file.
This may result from a file that was incorrectly
written.

Contact Allen-Bradley customer support.

Invalid filename specified for download.

Invalid destination file entered for the
download.

Enter a valid destination file name or use the
Browse button to search for a file.

Advertising