Rockwell Automation 2711-ND3 PanelBuilder v2.60 Software User Manual User Manual

Page 470

Advertising
background image

Troubleshooting

F–8

Publication 2711-6.0

1. DTL_XXX TSR could not be de-installed. Issue the uninstall

command again (CFG_XXX -u).

2. An attempt was made to uninstall the DTL_XXX driver

(CFG_XXX -u) when it was not installed.

The DTL_XXX TSR could not be de-installed. Issue the uninstall
command again (CFG_XXX -u).

CFG_XXX (0011) TSR still running, unable to deinstall

The 1784-KT2 communication card must have its memory and
interrupt software configured before INTERCHANGE Software is
run. Make sure you have configured your 1784-KT2 for a memory
address and that this memory address matches that entered in the
CFG_KT.INI file.

CFG_XXX (0012) KT not found at specified ‘memory’ (KT2 only)

These errors occur during communication card diagnostics. The
execution of these diagnostics is controlled by the statement
SELFTEST=OFF in CFG_KT.INI. If this line is commented out, the
diagnostics are run by default. If this line is uncommented and says
SELFTEST=ON, the diagnostics are run. To stop the diagnostics
from running, ensure that this line is not commented out and says
SELFTEST=OFF. The most common cause for these errors is that
the software or hardware setting of the memory address for your
communication card does not match that entered into CFG_KT.INI
for the type of card you are using.

CFG_KT (0013) KT memory diagnostic RAM 0 error

CFG_KT (0014) KT memory diagnostic RAM 1 error

CFG_KT (0015) KT counter diagnostic error

CFG_KT (0016) KT timer diagnostic error

CFG_KT (0017) KT serial diagnostic error

CFG_KT (0018) KT protocol downloading error

CFG_KT (0019) KT dualport memory error

If these errors occur, contact your Rockwell Software Inc. Global
Technical Support Representative.

CFG_KT (001d) Undefined error

CFG_KT (001e) Undefined error

CFG_KT (001f) Undefined error