E T H E R N E T C O M M U N I C A T I O N M O D U L E

Receive packet processor

268

Hardware Reference NS9215

Transferring a
frame to system
memory

The

RX_RD

logic manages the transfer of a frame in the RX_FIFO to system memory.

The transfer is enabled by setting the

ERXDMA

(enable receive DMA) bit in Ethernet

General Control Register #1.

Transferring a frame in the receive FIFO to system memory begins when the

RX_WR

logic notifies the

RX_RD

logic that a good frame is in the receive FIFO. Frames are

transferred to system memory using up to four rings (that is, 1, 2, or 3 rings can also
be used) of buffer descriptors that point to buffers in system memory. The
maximum frame size that each ring can accept is programmable. The first thing the

RX_RD

logic does, then, is analyze the frame length in the receive status FIFO to

determine which buffer descriptor to use.

The

RX_RD

logic goes through the four buffer descriptors looking for the optimum

buffer size. It searches the enabled descriptors starting with A, then B, C, and
finally D; any pools that are full (that is, the F bit is set in the buffer descriptor) are
skipped. The search stops as soon as the logic encounters an available buffer that is
large enough to hold the entire receive frame.

The pointers to the first buffer descriptor in each of the four pools are found in the
related Buffer Descriptor Pointer register (RXAPTR, RXBPTR, RXCPTR, RXDPTR).
Pointers to subsequent buffer descriptors are generated by adding an offset of

0x10

from this pointer for each additional buffer used.

Receive buffer
descriptor format

Receive buffer
descriptor format
description

The current buffer descriptor for each pool is kept in local registers. The current
buffer descriptor registers are initialized to the buffer descriptors pointed to by the
Buffer Descriptor Pointer registers, by setting the

ERXINIT

(enable initialization of

RX

buffer descriptor registers) bit in Ethernet General Control Register #1. The

initialization process is complete when

RXINIT

(

RX

initialization complete) is set in

the Ethernet General Status register. At the end of a frame, the next buffer
descriptor for the ring just used is read from system memory and stored in the
registers internal to the

RX_RD

logic.

Destination Address (not used)

Buffer Length (11 lower bits used)

Status

Source Address

0

OFFSET + 0

OFFSET + 4

OFFSET + 8

OFFSET + C

F

I

E

W

Reserved

31

15

16

30 29 28