S E R I A L C O N T R O L M O D U L E : S P I

SPI timing characteristics

444

Hardware Reference NS9215

Notes:

1

The unit clock refers to the SPI master clock.

2

The SPI master interface clock duty cycle is always at least 52/48. The numbers
shown here are for a 40 Mhz clock rate.

3

The numbers shown here are for a 40 Mhz clock rate. Usually, this parameter is
one half the SPI master interface clock period less 1.5ns.

4

This parameter does not depend on the SPI master interface clock rate.

SPI master timing
diagram

SPI slave timing
parameters

Notes:

1

The SPI slave interface clock duty cycle should be no worse than 60/40.

Mode3

S1

Mode0

CS#

MDO

CLK

MDI

S2 S3

S5

S4

S6

S9

S8

S7

Parm

Description

Min

Max

Unit

Notes

S11

CS# falling to CLK rising

50

ns

3

S12

CLK period low time

53

80

ns

1,2

S13

CLK period high time

53

80

ns

1,2

S14

Data input setup to CLK rising

10

ns

4

S15

Data input hold from CLK rising

15

ns

3

S16

Data output setup to CLK rising

80

ns

2

S17

Data output hold from CLK rising

67

ns

2

S18

CLK falling to CS# rising

50

ns

3

S19

CS# deassertion time

266

ns

2