MII Management Command register

296

Hardware Reference NS9215

Clocks field
settings

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

M I I M a n a g e m e n t C o m m a n d r e g i s t e r

Address: A060 0424

D04:02

R/W

CLKS

0x0

Clock select
Used by the clock divide logic in creating the MII
management clock, which (per the IEEE 802.3u
standard) can be no faster than 2.5 MHz.

Note:

Some PHYs support clock rates up to 12.5
MHz.

The AHB bus clock is used as the input to the clock
divide logic. See the “Clocks field settings” table for
settings that can be used with AHB clock (hclk)
frequencies.

D01

R/W

SPRE

0

Suppress preamble
0

Causes normal cycles to be performed

1

Causes the MII Management module to perform
read/write cycles without the
32-bit preamble field. (Preamble suppression is
supported by some PHYs.)

D00

R/W

Not used

0

Always write to 0.

Bits

Access

Mnemonic

Reset

Description

CLKS field

Divisor

AHB bus clock for 2.5 MHz
(max) MII management clock

AHB bus clock for 12.5 MHz
(max) MII management clock

000

4

001

4

37.5 MHz

010

6

74.9 MHz

011

8

100

10

101

20

37.5 MHz

110

30

74.9 MHz

111

40

Advertising