T I M I N G

Memory Timing

www.digiembedded.com

503

Ethernet timing

All AC characteristics are measured with 10pF, unless otherwise noted.

The table below describes the values shown in the Ethernet timing diagrams.

Notes:

1

Minimum specification is for fastest AHB bus clock of 88.5 MHz. Maximum specification is
for slowest AHB bus clock of 51.6 MHz.

2

C

load = 10pf for all outputs and bidirects.

3

Minimum specification is for fastest AHB clock at 88.5 MHz.

Ethernet MII
timing

Parm

Description

Min

Max

Unit

Notes

E1

MII tx_clk to txd, tx_en, tx_er

3

11

ns

2

E2

MII rxd, rx_en, rx_er setup to rx_clk rising

3

ns

E3

MII rxd, rx_en, rx_er hold from rx_clk rising

1

ns

E4

mdio (input) setup to mdc rising

10

ns

E5

mdio (input) hold from mdc rising

0

ns

2

E6

mdc to mdio (output)

18

34

ns

1, 2

E7

mdc period

80

ns

3

E6

E5

E 4

E 3

E2

E1

E7

E7

t x _c lk

tx d[ 3:0 ],tx _ en ,tx _ er

r x _c lk

r x d [3:0 ],r x _e n, rx _ er

md c

md io ( inpu t)

md io ( ou tpu t)