T I M I N G

Reset and edge sensitive input timing requirements

www.digiembedded.com

483

If an external device driving the reset or edge sensitive input on a Digi processor
cannot meet the 500ns maximum rise and fall time requirement, the signal must be
buffered with a Schmitt trigger device. Here are sample Schmitt trigger device part
numbers:

Manufacturer

Part Number

Description

Fairchild

NC7SP17

Single Schmitt trigger buffer,
available in 5-lead SC70 and 6-lead MicroPak packages

Philips

74LVC1G17GW

Single Schmitt trigger buffer,
available in 5-lead SC70 and SOT 353 packages

TI

SN74LVC1G17DC Single Schmitt trigger buffer,

available in 5-lead SC70 and SOT 353 packages

ON Semi

NL17SZ17DFT2

Single Schmitt trigger buffer,
available in 5-lead SC70 and SOT 353 packages.