E T H E R N E T C O M M U N I C A T I O N M O D U L E

Statistics registers

www.digiembedded.com

303

HT2

Address: A060 0508

Register bit assignment

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

S t a t i s t i c s r e g i s t e r s

Address: A060 0680 (base register)

The Statistics module has 39 counters and 4 support registers that count and save
Ethernet statistics. The Ethernet General Control Register #2 contains three
Statistics module configuration bits: AUTOZ, CLRCNT, and STEN. The counters
support a “clear on read” capability that is enabled when AUTOZ is set to 1.

Combined
transmit and
receive statistics
counters address
map

The combined transmit and receive statistics counters are incremented for each
good or bad frame, transmitted and received, that falls within the specified frame
length limits of the counter (for example, TR127 counts 65–127 byte frames). The
frame length excludes framing bits and includes the FCS (checksum) bytes. All
counters are 18 bits, with this bit configuration:

Bits

Access

Mnemonic

Reset

Description

D31:00

R/W

HT2

0x00000000

CRC 63:32

HT2

13

12

11

10

9

8

7

6

5

4

3

2

1

0

15

14

31

29

28

27

26

25

24

23

22

21

20

19

18

17

16

30

HT2

D31:18

R

Reserved

D17:00

R/W

Reset = 0x00000

Count (R/W)

Address

Register

Transmit and receive counters

R/W

A060_0680

TR64

Transmit & receive 64

Byte frame counter

R/W

A060_0684

TR127

Transmit & receive 65

to

127 Byte frame counter

R/W

A060_0688

TR255

Transmit & receive 128

to

255 Byte frame counter

R/W

A060_068C

TR511

Transmit & receive 256

to

511 Byte frame counter

R/W

A060_0690

TR1K

Transmit & receive 512

to

1023 Byte frame counter

R/W

Advertising