Yaskawa MotionWorks+ Windows Software User Manual

Page 101

Advertising
background image

MotionWorks+™

Electronic Cam Tool

95

6. Position/Editing Data

Set the position value corresponding to the phase value set in item 2 above.

7. Position/Change Value Adjustment

Set the increase/decrease value when the position value is set with the slide bar.

8. Position/Scale

Select the position display scale.

You can expand the graph to edit it accurately, using the current cursor position on the
graph as the origin.

9. Reference Graph

Select the reference graph to be displayed together with the edit graph.

For the setting method, refer to item 4, Setting the reference graph.

10. Setting Information

Based on the edit data, the effective torque, peak torque, and maximum rotation speed
are displayed.

These values are automatically calculated and displayed if the items with an [*] (for
Machine/Motor Information) are set in the Set Style window.

Effective torque and peak torque are displayed as a percentage (%) of rated torque.

11. Warning display

The boxes are displayed in green when the set values for the effective torque (no more
than 100%), peak torque (no more than 300%), and maximum rotation speed (under
the rated rotation speed) are within the tolerances, and displayed in red when they are
out of the tolerances.

Advertising