15 latch target – Yaskawa MotionWorks+ Windows Software User Manual

Page 156

Advertising
background image

Block Reference

MotionWorks+™

150

3.2.15 LATCH TARGET

Definition

The LATCH TARGET block synchronizes a move with a latch input. Specify the move
requirements as described in the properties table below. The latch input must occur
while the axis is between the latch start distance and the latch finish distance. Upon
successful latch input, the main axis decelerates to a stop at target distance +
mPosition_Latch_Main. If the latch does not occur within the window, the axis stops at
the default distance. Note: This block handles the enabling and disabling of the latch;
there is no need to use the LATCH block.

Properties

Acceleration:

The acceleration of the axis in user units/s

2

.

Deceleration:

The deceleration of the axis in user units/s

2

.

Default Distance: The final target at which the axis stops if a latch input did not

occur within the tolerance window. This is a relative distance
from the start of the move.

Latch Finish Distance:

The final position at which the latch is monitored. If the latch
occurs after this position, it is ignored, and the axis stops at the
default distance.

Property

Default

Minimum

Value

Maximum

Value

Base Units

Run

Time

Acceleration

N/A

32767

0 ms to rated speed

Yes

Deceleration

N/A

32767

0 ms from rated speed

Yes

Default Distance

N/A

-2147483648 2147483647 Encoder counts

Yes

Latch Finish Distance

N/A

-2147483648 2147483647 Encoder counts

Yes

Latch Start Distance

N/A

-2147483648 2147483647 Encoder counts

Yes

Target Distance

N/A

-2147483648 2147483647 Encoder counts

Yes

Velocity

N/A

0

200.00 % of rated speed

Yes

Wait for Completion

True

False

True

Configuration

No

Advertising