Electronic Cam Tool

MotionWorks+™

90

Scale Conversion

The graph scale is set with the maximum absolute value of the displayed data as 100.
Change the scale setting when comparing data whose upper and lower limit values are
different, or when comparing data at a designated section.

(a) Comparison of data with different upper and lower limit values

(Ex.) Display Cam Data A

Data Characteristics: PositionScale: 1000

Upper Limit: 1000

Lower Limit: 0

Display Data B

Data Characteristics: PositionScale: 800.0000416

Upper Limit: 800.0000416

Lower Limit: 0