Yaskawa MotionWorks+ Windows Software User Manual
Page 120
Programming Tools
MotionWorks+™
114
E0
224
Communication Timeout
(SGDH and MP940)
Amplifier could not communicate with the
MP940 connected to the DPRAM within
10 seconds of power up.
E2
226
Watch Dog Timer
between SGDH and
MP940
Out of synchronization. This is normal
when downloading a program. If
pGain_PositionLoop is set to zero, this
can cause AE2 alarm.
E7
231
Option Board Not
Connected
An option board (MP940) that was previ-
ously connected is no longer present. Use
amplifier function Fn14 to reset this alarm.
E9
233
MP940 Alarm
This alarm is generated by the MP940.
The MP940 alarms for more information.
EA
234
—
SGDH does not respond at power on or
after reset.
EB
235
—
SGDH initial access error. SGDH power
on start up confirmed, but response is
absent or faulty.
EC
236
—
Watch dog timer error. SGDH ran away or
WDT abnormal.
ED
237
—
Command Execution incomplete.
F1
241
Power Line Open Phase
One phase is not connected to the main
power supply.
CPF00
—
Digital Operator
Transmission Error
—
CPF01
—
Digital Operator
Transmission Error
—
SGDH Front
Panel (Hex)
mAlarm_Servo_
Code (Dec)
Alarm Name
Description