Yaskawa MotionWorks+ Windows Software User Manual

Page 21

Advertising
background image

MotionWorks+™

The Project Explorer

15

SGDH

When the SGDH module is selected, the following properties appear in the properties win-
dow: When an MP940 controller is used with an SGDH, it is recommended to set the
parameters of the amplifier through the controller instead of the front panel of the ampli-
fier. This method ensures that parameter values are retained with the project and down-
loaded properly.

Property

Default

Min

Max

Details (online Help message)

Pn000

90

0

0FB1

Function Selection Basic Switches. See sections 5.1.1 and
5.3.5 of SGDH manual.

Pn001

0

0

1122

Function Selection Application Switches 1. See sections 5.1.2,
5.4.2, and 5.5.7 of SGDH manual.

Pn002

11

0

4113

Function Selection Application Switches2. See sections 5.2.8,
5.2.9, and 5.7.2 of SGDH manual.

Pn003

2

0

00FF

Function Selection Application Switches 3. See section 6.5 of
SGDH manual.

Pn100

40

1

2000

Speed Loop Gain in Hz. This is an important component of
servo tuning, this parameter acts as the derivative gain. See
section 6.2.1 of SGDH manual.

Pn101

2000

15

51200 Speed Loop Integral Time Constant in 0.01ms. This is an impor-

tant component of servo tuning. See section 6.2.1 of SGDH
manual.

Advertising