The Project Explorer
19
COM1
When the COM1 module is selected, the following properties appear in the properties
window.
Address:
Select between 0 and 63.
Baud Rate:
The choices are 9600 and 19200bps.
Function:
Fext at “Slave”.
Protocol:
This is fixed at Memobus for MW+ projects.
Transmission Mode:
This is fixed at RTU for MW+ projects.
Property
Default
Minimum
Maximum
Detail
Address
1
0
63
—
Baud Rate
19200
9600
19200
—
Function
Slave
—
—
—
Protocol
Memobus
—
—
Fixed
Transmission Mode
RTU
—
—
Fixed