1 user unit conversion – Yaskawa MotionWorks+ Windows Software User Manual

Page 133

Advertising
background image

MotionWorks+™

User Unit Conversion

127

3.1 User Unit Conversion

Throughout the block definition which follows in this section, the minimum and
maximum range of properties are listed in MP940 base units. The following calcula-
tions are provided to aid in determining the minimum and maximum values in user
units.

Accel and Decel Formulas

The following formula shows conversion from user units/s

2

to milliseconds to rated

speed. In the example, assume the rated motor speed is 3000rpm, the feed constant is 9
user units per machine revolution, and the acceleration setting is 100 user units per s

2

.

Conversely, the following formula can be used to determine minimum and maximum
user units.

Accel

Setting

Rated

Motor

Speed

Convert to

Seconds

Feed

Constant

Gear Box

Convert to

Milliseconds

Base Units

Base Units

Rated

Motor

Speed

Convert to

Seconds

Feed

Constant

Gear Box

Convert to

Milliseconds

ACCEL

Setting

1s

2

100 Units

-------------------------

3000 rev

1 min

-----------------------

×

60s

1 min

--------------

÷

9 units

1 rev

-----------------

×

2 input

1 output

---------------------

×

100 ms

1 s

-------------------

×

9000 ms

=

1

32768ms

------------------------

3000rev

1 min

----------------------

×

60s

1 min

--------------

÷

9 units

1 rev

-----------------

×

2 input

1 output

---------------------

×

1000ms

1s

---------------------

×

27.465 units

1s

2

---------------------------

=

Advertising