Yaskawa MotionWorks+ Windows Software User Manual

Page 91

Advertising
background image

MotionWorks+™

Electronic Cam Tool

85

5. Cursor Position/Phase

Enter the phase value or set with the arrow buttons.

By clicking a point on the cam graph, the phase and position values at which the
mouse is pointing are displayed.

The X axis of the cam graph (1) shows the phase (master) value and the Y axis shows
the position (slave) value.

6. Cursor Position/Position

The position value corresponding to the phase value set in step 5 (above) is displayed.

7. Speed Data/Scale (Y-axis) Selection

Select the graph display type of the speed data graph (2).

By selecting the radio button from Actual Data and Rated Rotation Speed Ratio (%),
the speed control graph changes.

8. Acceleration Data/Scale (Y-axis) Selection

Select the graph display type of the acceleration data graph (3).

By selecting the radio button from Actual Data and Rated Torque Ratio (%), the accel-
eration control graph changes.

9. Data/Maximum Value

The maximum values of speed, acceleration and jerk are displayed.

10. Data/Cursor Positions

The speed, acceleration and jerk of the phase and position values at which the mouse is
pointing on the cam graph are displayed.

Advertising